High inhaled oxygen concentration quadruples exhaled CO in healthy volunteers monitored by a highly sensitive laser spectrometer - Archive ouverte HAL Accéder directement au contenu
Article Dans Une Revue Scientific Reports Année : 2019

High inhaled oxygen concentration quadruples exhaled CO in healthy volunteers monitored by a highly sensitive laser spectrometer

Résumé

Carbon monoxide (CO) monitoring in human breath is the focus of many investigations as CO could possibly be used as a marker of various diseases. Detecting CO in human breath remains a challenge because low concentrations (
Fichier principal
Vignette du fichier
Brenckmann_et_al-2019-Scientific_Reports.pdf (1.48 Mo) Télécharger le fichier
Origine : Fichiers éditeurs autorisés sur une archive ouverte
Loading...

Dates et versions

hal-02269754 , version 1 (23-08-2019)

Identifiants

Citer

Vivien Brenckmann, Irène Ventrillard, Daniele Romanini, Kévin Jaulin, Pascale Calabrese, et al.. High inhaled oxygen concentration quadruples exhaled CO in healthy volunteers monitored by a highly sensitive laser spectrometer. Scientific Reports, 2019, 9 (1), ⟨10.1038/s41598-019-48789-8⟩. ⟨hal-02269754⟩