A biomechanical breast model evaluated with respect to MRI data collected in three different positions

Anna Mîra 1 Ann-Katherine Carton 2 Serge Muller 2 Yohan Payan 1
1 TIMC-IMAG-GMCAO - Gestes Medico-chirurgicaux Assistés par Ordinateur
TIMC-IMAG - Techniques de l'Ingénierie Médicale et de la Complexité - Informatique, Mathématiques et Applications, Grenoble - UMR 5525
Abstract : Background: Mammography is a specific type of breast imaging that uses low-dose X-rays to detect cancer in early stage. During the exam, the women breast is compressed between two plates in order to even out the breast thickness and to spread out the soft tissues. This technique improves exam quality but can be uncomfortable for the patient. The perceived discomfort can be assessed by the means of a breast biomechanical model. Alternative breast compression techniques may be computationally investigated trough finite elements simulations. Methods: The aim of this work is to develop and evaluate a new biomechanical Finite Element (FE) breast model. The complex breast anatomy is considered including adipose and glandular tissues, muscle, skin, suspensory ligaments and pectoral fascias. Material hyper-elasticity is modeled using the Neo-Hookean material models. The stress-free breast geometry and subject-specific constitutive models are derived using tissues deformations measurements from MR images. Findings: The breast geometry in three breast configurations were computed using the breast stress-free geometry together with the estimated set of equivalent Young's modulus (Ebreast_r=0.3 kPa, Ebreast_l=0.2 kPa, Eskin=4 kPa, Efascia=120 kPa). The Hausdorff distance between estimated and measured breast geometries for prone, supine and supine tilted configurations is equal to 2.17 mm, 1.72mm and 5.90mm respectively. Interpretation: A subject-specific breast model allows a better characterization of breast mechanics. However, the model presents some limitations when estimating the supine tilted breast configuration. The results show clearly the difficulties to characterize soft tissues mechanics at large strain ranges with Neo-Hookean material models.
Liste complète des métadonnées

https://hal.archives-ouvertes.fr/hal-01929974
Contributeur : Yohan Payan <>
Soumis le : jeudi 22 novembre 2018 - 13:33:04
Dernière modification le : jeudi 21 mars 2019 - 14:56:09
Document(s) archivé(s) le : samedi 23 février 2019 - 13:32:28

Fichier

Clinical Biomechanics 2018 Mir...
Fichiers produits par l'(les) auteur(s)

Identifiants

Collections

Citation

Anna Mîra, Ann-Katherine Carton, Serge Muller, Yohan Payan. A biomechanical breast model evaluated with respect to MRI data collected in three different positions. Clinical Biomechanics, Elsevier, 2018, 60, pp.191 - 199. ⟨10.1016/j.clinbiomech.2018.10.020⟩. ⟨hal-01929974⟩

Partager

Métriques

Consultations de la notice

42

Téléchargements de fichiers

70